The internal splice is 1-1/2 tubing with a 3/8" wall

MEGABATTEN Connector Strip

Voted Best Electrical Hardware Product
Gold Star Award
PLSN, 2018

MEGABATTEN Connector Strip

Detail of the MEGABATTEN installed in the Fox News Studio

MEGABATTEN Connector Strip

MEGABATTEN installation in the Fox News Studio in New York City

MEGABATTEN Connector Strip

MEGABATTEN Connector Strip

Curved MEGABATTEN Installation
Willowbrook
Photo Courtesy of Redwire AV

MEGABATTEN Connector Strip

The MEGABATTEN has hinges that allow it to be folded into 8' segments for shipping.

MEGABATTEN Connector Strip

MEGABATTENS folded for shipping

MEGABATTEN Connector Strip

Configure your MEGABATTEN here.

Get a quote on your MEGABATTEN's here.

Power and data in a pipe with the new MEGABATTEN connector strip. The patented MEGABATTEN dispenses with the traditional connector strip square or rectangular electrical enclosures by placing all of the wiring inside the pipe. U.S. Patent No. 10,955,096 issued March 23, 2021.

Fixtures and scenery may be located over the entire length of the MEGABATTEN, even directly over unused outlets.

Pockets are milled in the wall of extra strong schedule 80 aluminum pipe to recess the power and data receptacles inside the circumference of the pipe. 20-amp Edison receptacles are spaced every 16” with a 5 pin XLR receptacle right next to it for data. The new LED fixtures require only a few circuits, but up to six 20-amp circuits are available in the MEGABATTEN if needed.

The MEGABATTEN is ETL listed to the UL 1573 Stage and Studio standard as a connector strip in the US, and in Canada under Surface Raceway Systems (R2017) [CSA C22.2#62:1993 Ed.2+G1]. The MEGABATTEN is listed to support a load of 30 pounds per linear foot when supported on a maximum of 8-foot centers.(5' in Canada) Power and DMX is available anywhere a light is placed on the MEGABATTEN. Connecting into the MEGABATTEN re-originated DMX outlets eliminates the need to run DMX from fixture to fixture.

Download Spec Sheet (PDF)